Selection of the proper TE Cooler for a
specific application requires an evaluation of the total system in which the
cooler will be used. For most applications it should be possible to use one of
the standard module configurations while in certain cases a special design may
be needed to meet stringent electrical, mechanical, or other requirements.
Although we encourage the use of a standard device whenever possible, Ferrotec
America specializes in the development and manufacture of custom TE modules and
we will be pleased to quote on unique devices that will exactly meet your
requirements.
The overall cooling system is
dynamic in nature and system performance is a function of several interrelated
parameters. As a result, it usually is necessary to make a series of iterative
calculations to "zero-in" on the correct operating parameters. If there is any
uncertainty about which TE device would be most suitable for a particular application,
we highly recommend that you contact our engineering staff for assistance.
Before starting the actual TE
module selection process, the designer should be prepared to answer the following
questions:
- At what temperature must the cooled object
be maintained?
- How much heat must be removed from the cooled
object?
- Is thermal response time important? If yes,
how quickly must the cooled object change temperature after DC power has
been applied?
- What is the expected ambient temperature?
Will the ambient temperature change significantly during system operation?
- What is the extraneous heat input (heat
leak) to the object as a result of conduction, convection, and/or radiation?
- How much space is available for the module
and heat sink?
- What power is available?
- Does the temperature of the cooled object
have to be controlled? If yes, to what precision?
- What is the expected approximate temperature
of the heat sink during operation? Is it possible that the heat sink temperature
will change significantly due to ambient fluctuations, etc.?
Each application obviously will have its own set of requirements that likely
will vary in level of importance. Based upon any critical requirements that
can not be altered, the designer's job will be to select compatible components
and operating parameters that ultimately will form an efficient and reliable
cooling system. A design example is presented in section 9.5 to illustrate the
concepts involved in the typical engineering process.
USE OF TE MODULE PERFORMANCE
GRAPHS: Before beginning any thermoelectric design activity it is necessary
to have an understanding of basic module performance characteristics. Performance
data is presented graphically and is referenced to a specific heat sink base
temperature. Most performance graphs are standardized at a heat sink temperature
(Th) of +50°C and the resultant data is usable over a range of approximately
40°C to 60°C with only a slight error. Upon request, we can supply module performance
graphs referenced to any temperature within a range of -80°C to +200°C.
To demonstrate the use of these
performance curves let us present a simple example. Suppose we have a small
electronic "black box" that is dissipating 15 watts of heat. For the electronic
unit to function properly its temperature may not exceed 20°C. The room ambient
temperature often rises well above the 20°C level thereby dictating the use
of a thermoelectric cooler to reduce the unit's temperature. For the purpose
of this example we will neglect the heat sink (we cannot do this in practice)
other than to state that its temperature can be maintained at 50°C under worst-case
conditions. We will investigate the use of a 71-couple, 6-ampere module to provide
the required cooling.
GRAPH: Qc vs. I This graph,
shown in Figure (9.1), relates a module's heat pumping capacity (Qc) and temperature
difference (DT) as a function of input current (I). In this example, established
operating parameters for the TE module include Th = 50°C, Tc = 20°C, and Qc
= 15 watts. The required DT = Th-Tc = 30°C.
It is necessary first to determine
whether a single 71-couple, 6-ampere module is capable of providing sufficient
heat removal to meet application requirements. We locate the DT=30 line and
find that the maximum Qc value occurs at point A and with an input current of
6 amperes. By extending a line from point A to the left y-axis, we can see that
the module is capable of pumping approximately 18 watts while maintaining a
Tc of 20°C. Since this Qc is slightly higher than necessary, we follow the DT=30
line downward until we reach a position (point B) that corresponds to a Qc of
15 watts. Point B is the operating point that satisfies our thermal requirements.
By extending a line downward from point B to the x-axis, we find that the proper
input current is 4.0 amperes.

Figure (9.1)
Heat Pumping Capacity Related to Temperature Differential
as a Function of Input Current for a 71-Couple, 6-Ampere Module
GRAPH:
Vin vs. I This graph, shown in Figure (9.2),
relates a module's input voltage (Vin) and temperature difference (DT) as a
function of input current (I). In this example, parameters for the TE module
include Th = 50°C, DT = 30°C, and I = 4.0 amperes. We locate the DT=30 line
and, at the 4.0 ampere intersection, mark point C. By extending a line from
point C to the left y-axis, we can see that the required module input voltage
(Vin) is approximately 6.7 volts.

Figure (9.2)
Input Voltage Related to Temperature Differential as a
Function of Input Current for a 7I-Couple, 6-Ampere Module
GRAPH:COP
vs. I This graph, shown in Figure (9.3), relates a module's coefficient
of performance (COP) and temperature differential (DT) as a function of input
current (I). In this example, parameters for the TE module include Th = 50°C,
DT = 30°C, and I = 4.0 amperes.
We locate the DT=30 line and,
at the 4.0 ampere intersection, mark point D. By extending a line from point
D to the left y-axis, we can see that the module's coefficient of performance
is approximately 0.58.

Figure (9.3)
Coefficient of Performance Related to Temperature Differential as a
Function of Input Current for a 71-Couple, 6-Ampere Module
Note that COP is a measure of
a module's efficiency and it is always desirable to maximize COP whenever possible.
COP may be calculated by:

An additional graph of Vin vs.
Th, of the type shown in Figure (9.4), relates a module's input voltage (Vin)
and input current (I) as a function of module hot side temperature (Th). Due
to the Seebeck effect, input voltage at a given value of I and Th is lowest
when DT=O and highest when DT is at its maximum point. Consequently, the graph
of Vin vs. Th usually is presented for a DT=30 condition in order to provide
the average value of Vin.

Figure (9.4)
Input Voltage Related to Input Current as a Function of
Hot Side Temperature for a 71-Couple, 6-Ampere Module
DESIGN EXAMPLE: To illustrate
the typical design process let us present an example of a TE cooler application
involving the temperature stabilization of a laser diode. The diode, along with
related electronics, is to be mounted in a DIP Kovar housing and must be maintained
at a temperature of 25°C. With the housing mounted on the system circuit board,
tests show that the housing has a thermal resistance of 6°C/watt. The laser
electronics dissipate a total of 0.5 watts and the design maximum ambient temperature
is 35°C.
It is necessary to select a TE
cooling module that not only will have sufficient cooling capacity to maintain
the proper temperature, but also will meet the dimensional requirements imposed
by the housing. An 18-couple, 1.2 ampere TE cooler is chosen initially because
it does have compatible dimensions and also appears to have appropriate performance
characteristics. Performance graphs for this module will be used to derive relevant
parameters for making mathematical calculations. To begin the design process
we must first evaluate the heat sink and make an estimate of the worst-case
module hot side temperature (Th). For the TE cooler chosen, the maximum input
power (Pin) can be determined from Figure (9.5) at point A.
- Max. Module Input Power (Pin) = 1.2 amps
x 2.4 volts = 2.9 watts
- Max. Heat Input to the Housing = 2.9 watts
+ 0.5 watts = 3.4 watts
- Housing Temperature Rise = 3.4 watts x 6°C/watt
= 20.4°C
- Max. Housing Temperature (T,) = 35°C ambient
+ 20.4°C rise = 55.4°C Since the hot side temperature (Th) of 55.4°C is
reasonably close to the available Tin = 50°C performance graphs, these graphs
may be used to determine thermal performance with very little error.

Figure (9.5)
Vin vs. I Graph for an 18-Couple, I.2 Ampere Module
Now that we have established
the worst-case Th value it is possible to assess module performance.
Module Temperature Differential
(DT) = Th - Tc = 55.4 - 25 = 30°C

Figure (9.6)
Qc vs. I Graph for an 18-Couple, 1.2 Ampere Module
From Figure (9.6) it can be seen
that the maximum heat pumping rate (Qc) for DT=30 occurs at point B and is approximately
0.9 watts. Since a Qc of only 0.5 watts is needed, we can follow the DT=30 line
down until it intersects the 0.5 watt line marked as point C. By extending a
line downward from point C to the x-axis, we can see that an input current (I)
of approximately 0.55 amperes will provide the required cooling performance.
Referring back to the Vin vs. I graph in Figure (9.5), a current of 0.55 amperes,
marked as point D, requires a voltage (Vin) of about 1.2 volts. We now have
to repeat our analysis because the required input power is considerably lower
than the value used for our initial calculation. The new power and temperature
values will be:
- Max. Module Input Power (Pin) = 0.55 amps
x 1.2 volts = 0.66 watts
- Max. Heat Input to the Housing = 0.66 watts
+ 0.50 watts = 1.16 watts
- Housing Temperature Rise = 1.16 watts x
6°C/watt = 7°C
- Max. Housing Temperature (Th) = 35°C ambient
+ 7°C rise = 42°C
Module Temperature Differential (DT) = Th-Tc = 42°C-25°C = 17°C
It can be seen that because we
now have another new value for Th it will be necessary to continue repeating
the steps outlined above until a stable condition is obtained. Note that calculations
usually are repeated until the difference in the Th values from successive calculations
is quite small (often less that 0.1°C for good accuracy). There is no reason
to present the repetitive calculations here but we can conclude that the selected
18-couple TE module will function very well in this application. This analysis
clearly shows the importance of the heat sink in any thermoelectric cooling
application.
USE OF MULTIPLE MODULES:
Relatively large thermoelectric cooling applications may require the use of
several individual modules in order to obtain the required rate of heat removal.
For such applications, TE modules normally are mounted thermally in parallel
and connected electrically in series. An electrical series-parallel connection
arrangement may also be used advantageously in certain instances. Because heat
sink performance becomes increasingly important as power levels rise, be sure
that the selected heat sink is adequate for the application.